Inicio ProductosInstrumento de ignición

AS/NZS 1530.3 Ingitability Tester for Fire Tests on Building Materials

AS/NZS 1530.3 Ingitability Tester for Fire Tests on Building Materials

    • AS/NZS 1530.3 Ingitability Tester for Fire Tests on Building Materials
    • AS/NZS 1530.3 Ingitability Tester for Fire Tests on Building Materials
    • AS/NZS 1530.3 Ingitability Tester for Fire Tests on Building Materials
  • AS/NZS 1530.3 Ingitability Tester for Fire Tests on Building Materials

    Datos del producto:

    Lugar de origen: PORCELANA
    Nombre de la marca: AI
    Certificación: ISO
    Número de modelo: AIC1530-3

    Pago y Envío Términos:

    Cantidad de orden mínima: 1 JUEGO Probador de Ingitabilidad AS/NZS 1530.3
    Precio: Negociable
    Detalles de empaquetado: Probador de ingitabilidad AS/NZS 1530.3 embalado en caja de madera contrachapada
    Tiempo de entrega: 60 días
    Condiciones de pago: Western Union, T/T, L/C, MoneyGram
    Capacidad de la fuente: 50 conjuntos por mes
    Contactar ahora
    Descripción detallada del producto
    Estándar de prueba: AIC1530-3 Función: Prueba de inflamabilidad, propagación de llama, liberación de calor y liberación de humo
    Objeto de prueba: Materiales de construcción Peso: 350 kg
    Dimensión del controlador: 600*750*1600mm3 Dimensión del banco de pruebas: 1400*1000*2200m m
    Tamaño de muestra: 710mmx610mm Garantía: 1 año

    Introduction
    AS/NZS 1530.3  Ingitability Tester is designed according to AS/NZS1530.3.
    The tester heats samples via a gas radiant plate and calibrate with a heat flow meter. Test sample is placed in a vertical position, near the radiation plate, exposed in a clear area calibrated radiation flux.Close to the pilot flame is assembled with the test sample, but not in contact with the test sample.After ignition, it can record ignition time, flame propagation time, heat release integral, smoke release, etc.


    Feature
    1, All structural components of AS/NZS 1530.3 Ingitability Tester are made of stainless steel, nice appearance, corrosion resistance;
    2, Sample fixture could be movable to adjust the distance to the radiant panel.
    3, Ignition sources: radiation plate and two pilot flame burners;
    4, One pilot flame burner is fixed before the sample at 15mm from the front face of the sample and 50mm above the center of the samples. And the other burner could be moved before the sample.
    5, Flame height is controlled by the imported flow control meter.
    6,Samples size: 710mmx610mm;
    7, Stainless steel hood and flue to collect the smoke of specimens. Hood size:1140mmx1140mm; smoke tube is dia.305mm;
    8, Radiant panel size:300mmx300mm; With porous fire-brick surface.
    9, Radiation plate temperature probe: prevent flames turned the heat radiating plate rear side;
    10, Precise gas and airflow control to realized the radiant panel heat adjustment.
    11, AS/NZS 1530.3 Ingitability Tester is provided with heat flux senor fixture to calibrate the radiation level according to standard request 2.4kw/m2;
    12, Two shields could be removed as a standard request.
    13,19" rack to measure the flame spread rate analysis, critical flow, heat release rate
    14, AS/NZS 1530.3 Ingitability Tester has an exhaust fan.

    Optical system
    1, The optical system comprising a light source color temperature is 2900 ± 100 K incandescent, light-receiving silicon photodiode with an optical path test shutter, 0% and 100%, to facilitate the use of calibration;
    2, AS/NZS 1530.3 Ingitability Tester adopts imported light battery module measuring light attenuation. The system automatically calculates and generates a light transmittance curve translucent; printable Scribble
    3, One button automatic and five-level (0,25%,50%,75%,100%)calibration system by computer.

    Test System
    1, The United States imported Metherm thermopile type heat flow meter-Design range 0~10k W/m², the accuracy of heat flow meter is ± 3%, repeatability is ± 0.5%.
    2, Gas supply: with a valve, zero-pressure valve, tempering valves, solenoid valves, and a mixer, the mixed air and fuel gas supplied to the radiation plate.
    3, All radiant panel combustion control system safety explosion-proof, check valve, cut off the gas solenoid valve prevents the gas reflux
    4, The camera can observe a situation and save the test program (Optional)
    5, Data acquisition system can store the data of ignition time, flame propagation time, heat release integral,
    smoke release, etc.
    6, Radiation plate burner system is fully automated, with spark ignition and safety protection the system;
    7, Labview control system, user-friendly, easy to operate, precise control;
    8, Signal acquisition and processing module and the air volume control module circuit linked by a programmable logic controller;
    9, 10kV spark ignition, with safety cease-fire devices.
    10, Automatic ignition system; Automatic timing; Expire automatically turn off;
    11, Window+Labview system to realize automatic test system
    12, The tester is equipped with audible alarm and alarm display function accidents.
    13, The control box USB / RS232 serial port, external desktop/notebook computer operation control, free to print the test report.
    14, AS/NZS 1530.3 Ingitability Tester has an automatic smoke density calibration system.

     

    Installation Requirements of AS/NZS 1530.3 Ingitability Tester:

    1 Power supply AC220V±10%,50Hz,5KW
    2 Size of test stand 1400*1000*2200mm
    3 Dimension of controller 600*750*1600mm3
    4 Weight 350KG

     

    AS/NZS 1530.3 Ingitability Tester for Fire Tests on Building Materials

    Contacto
    Advanced Instruments Co.,Ltd

    Persona de Contacto: Mrs. Sandy

    Envíe su pregunta directamente a nosotros (0 / 3000)

    Otros productos