UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC

UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC

    • UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC
    • UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC
    • UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC
  • UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC

    Datos del producto:

    Lugar de origen: PORCELANA
    Nombre de la marca: AI
    Certificación: ISO
    Número de modelo: A91

    Pago y Envío Términos:

    Cantidad de orden mínima: 1 set
    Precio: Negociable
    Detalles de empaquetado: Panel duro
    Tiempo de entrega: 20 días
    Condiciones de pago: L/C, T/T, Western Union
    Capacidad de la fuente: 20 juegos por mes
    Contactar ahora
    Descripción detallada del producto
    Estándares de prueba: ASTM UOP960 Solicitud: Medición de trazas de hidrocarburos oxigenados en corrientes de hidrocarburos líquidos
    Método de prueba: GC Garantía: 1 año
    Fuente de alimentación: AC220V ± 10% 50Hz palabra clave: Cromatógrafo de gases UOP960

     

    UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC

    UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC

     

    Flow chart of Measuring Trace Oxygenated Hydrocarbons in Naphtha

     

    2 Configuration

    Item CAT NO. DESCRIPTION QTY
    1 G2091A A91 Plus CG 1
    2 G2011B Software 1
    3 1790M Start-up kit A(including sample injection port))  
    4 #210 FID 2
    5 #120 SISL Capillary Injection Port (0~100 psi) 1
    6 PN5.132.002 One way PCM Pressure Control Module 1
    7 #513 Three automatic valves,with valve box heating and pipeline 1
    8 #561 Six way rotor valve 2
    9 #450 Independent heating column(at the back of FID detector) 1
    10 #515 Side Valve Box 1
    11 #542 Four way liquid injection valve(1.0ul volume,75C and 1000 psi max) 1
    12 #360 Liquid injection valve back pressure damping system assembly 1
    13 ECM.7.342.001 2um stainless steel gas filter 1
    14 #610 Sample ring(0.5mL) 1
    15 PN5.150.006 Deoxidation trap 1
    16 PN5.150.004 Dewatering trap 1
    17 PN5.150.005 Dealkylation trap 1
    18 Pipeline Capillary column 1m*0.53 1
    19 Column 1 20m*530um ID*5um MXT-1,Restek Cat.No.71812 1
    20 Column 2 10m*530 u ID*10 uLowox 1
    21 Column 3 30m*0.53 1
    22 Computer Lenovo 1

     