Inicio ProductosAnálisis de Producción de Humo

16 CFR 1633 Flammability of Mattress Test Chamber with Imported Gas Analyzer

16 CFR 1633 Flammability of Mattress Test Chamber with Imported Gas Analyzer

    • 16 CFR 1633 Flammability of Mattress Test Chamber with Imported Gas Analyzer
    • 16 CFR 1633 Flammability of Mattress Test Chamber with Imported Gas Analyzer
    • 16 CFR 1633 Flammability of Mattress Test Chamber with Imported Gas Analyzer
  • 16 CFR 1633 Flammability of Mattress Test Chamber with Imported Gas Analyzer

    Datos del producto:

    Lugar de origen: PORCELANA
    Nombre de la marca: AI
    Certificación: ISO
    Número de modelo: AIC-9705

    Pago y Envío Términos:

    Cantidad de orden mínima: 1 set
    Precio: Negociable
    Detalles de empaquetado: Caja de madera contrachapada
    Tiempo de entrega: 90 dias
    Condiciones de pago: Unión occidental, T/T, L/C
    Contactar ahora
    Descripción detallada del producto
    Estándar de prueba: ISO 9705, EN 14390,16 CFR 1633 Peso: 7,500 kg
    Dimensión: 11.725 (W) x4,000 (D) x4,750 (H) milímetro Tamaño de la consola: 600 (W)×750 (D)×1800 (H) milímetro
    Color: Blanco Keyward: Inflamabilidad de los equipos de prueba de colchones

    16 CFR 1633 Flammability of Mattress Test Chamber

    16 CFR 1633 Flammability of Mattress Test Chamber with Imported Gas Analyzer

     

    INTRODUCTION

    This test chamber is designed according to GB/T 34441-2017, it can test combustion performance of soft furniture mattress exposed to flame ignition source.

    The test part of this equipment can meet the requirements of GB/T 20286, GA 111-1995, ISO 9705-2, GB/T 27904-2011 and GB/T 25207-2010 "Test Method for Solid Room Fire of Surface Products"

     

    Standards

    • GB/T 34441-2017
    • GB/T 20286-2006
    • GA 111-1995
    • ISO 9705-2
    • GB/T 27904-2011
    • 16 CRF 1633.

     

    Main features

    1.Testing room: Testing room can be built as closed or open(CFR 1633 standard requires test room can be built as closed or open.)

    Closed test room:

    The room is made of rock wool board. There are no openings except door and video surveillance windows

    The size of the test room is 3660 ± 25mm in length, 3050 ± 25mm in width and 2438 ±25mm in height.

    • The door is 2032 ± 6 mm high and 965 ± 6 mm wide.
    • Quartz glass monitor window, size 150x150mm.
    • The fume hood is located outside the door (smoke outlet) to collect smoke;

    Open test room:

    • The fume hood is positioned directly above the sample and the bottom edge is 2400 mm away from the ground.
    • Conical collector size: 3000mm X 3000mm, height 1000mm
    •  The conical collector has 900mm X 900mm X 900mm X 900mm cubic mixing chamber on the top, and the mixer is installed inside

     

    2.The smoke exhaust pipe consists of a diversion section (x2), a straight section, a measuring section and a fan

    The measuring section is equipped with wind speed probe, thermocouple, optical system and sampler.

    Smoke exhaust capacity of fan is not less than 0.5m³/s

     

    3.Control cabinet

    • 19 inch standard cabinet, simple appearance, science and technology
    • Control system center, integrated computer, display, analyzer, cold trap, control and data acquisition system.
    • 19 inch display, Labview control software, electronic control and pneumatic configuration panel.
    • Computer: CPU I3, memory 4G, hard disk 500G Win7/Win10 system

     

     