Inicio ProductosInstrumento de prueba eléctrica

25KVA Primary Current Injection Test Kit High Current Generator Instrument

25KVA Primary Current Injection Test Kit High Current Generator Instrument

    • 25KVA Primary Current Injection Test Kit High Current Generator Instrument
    • 25KVA Primary Current Injection Test Kit High Current Generator Instrument
    • 25KVA Primary Current Injection Test Kit High Current Generator Instrument
  • 25KVA Primary Current Injection Test Kit High Current Generator Instrument

    Datos del producto:

    Lugar de origen: PORCELANA
    Nombre de la marca: AI
    Certificación: ISO
    Número de modelo: PCI-2

    Pago y Envío Términos:

    Cantidad de orden mínima: 1 set
    Precio: Negociable
    Detalles de empaquetado: Caja de cartón
    Tiempo de entrega: 15 días
    Condiciones de pago: T/T, Western Union, L/C
    Capacidad de la fuente: 100000 conjuntos por mes
    Contactar ahora
    Descripción detallada del producto
    Fuente de alimentación: CA 220 V o CA 400 V, 45 Hz ~ 65 Hz Mostrar: Digital
    palabra clave: Kit de prueba de inyección de corriente primaria Corriente de salida: 500A~25KVA
    Capacidad de salida: 3KVA-15KVA Garantía: 1 año

     

    Primary Current Injection Tester System with Circuit Breaker Timer

    25KVA Primary Current Injection Test Kit High Current Generator Instrument

     

    I. Introduction:

    PCI series primary current injection tester is applied in power system for circuit breaker test, protection system test and current transformer test. The current injection test set generates a high current from power supply to simulate the rated current or fault current in the primary circuit of power equipment.

    The 1000A/15KVA primary injection test system is designed in integrated model.

     

     

    Features:

    1 High current output injected to the main circuit of power line to simulate the fault current. Then check whether the protection system will be operated according to the design.
    2 High current output injected to the primary of current transformer and then measure the inducted current from secondary
    by error measurement instrument to check the ratio error and phase displacement of CT.
    3 High current output injected to the main circuit of circuit breaker to simulate the rated current in primary. Then check the stability of circuit breaker according to the temperature rise procedure.

    4 This primary current injection test set is also considered as a AC high current source in power equipment or cable test.

    5.Current is measured from the secondary of current transformer which is installed in the internal of the current booster.

     

     

    III. Specifications:

    1 Power supply AC220V or AC 400V, 45Hz~65Hz. The power supply voltage is depends on the power output capacity, as below.
    2 Typical output current

    500A or 1000A or 2000A

    Typical output capacity 3KVA or 5KVA or10KVA or15KVA
    It can be customized according to your requirements from above specs

    3 Impendence voltage 8%
    4 Idle current 6%
    5 Current distortion <5%
    6 Display unit 4 and 1/2 digitals current meter
    7 Maximum measurement error 0.5%RDG+5D
    8 Optional timer 1)4 digital timer from 0~9999s / 0~999.9s /0~99.99s, accuracy 0.5%RDG+5D
    2)5 digital timer from 0~99999s / 0~9999.9s /0~999.99s, accuracy 0.2%RDG+2D
    3)6 digital timer from 0~999999s / 0~99999.9s /0~9999.99s, accuracy 0.1%RDG+1D
    9 Work temperature 0~40 C, Humidity <90%

     

     

    Photo of 25KVA/2500A Primary Current Injection Test System

    25KVA Primary Current Injection Test Kit High Current Generator Instrument

    Contacto
    Advanced Instruments Co.,Ltd

    Persona de Contacto: Mrs. Sandy

    Envíe su pregunta directamente a nosotros (0 / 3000)