Inicio ProductosEquipo de ensayo de inflamabilidad

Contact Heat Transimmision Test Apparatus EN 702 and ISO 12127-1

Contact Heat Transimmision Test Apparatus EN 702 and ISO 12127-1

    • Contact Heat Transimmision Test Apparatus EN 702 and ISO 12127-1
    • Contact Heat Transimmision Test Apparatus EN 702 and ISO 12127-1
    • Contact Heat Transimmision Test Apparatus EN 702 and ISO 12127-1
    • Contact Heat Transimmision Test Apparatus EN 702 and ISO 12127-1
  • Contact Heat Transimmision Test Apparatus EN 702 and ISO 12127-1

    Datos del producto:

    Lugar de origen: PORCELANA
    Nombre de la marca: AI
    Certificación: ISO
    Número de modelo: CHT

    Pago y Envío Términos:

    Cantidad de orden mínima: 1 set
    Precio: Negociable
    Detalles de empaquetado: Caja de madera contrachapada
    Tiempo de entrega: 60 días
    Condiciones de pago: Unión occidental, T/T, L/C
    Capacidad de la fuente: 20 juegos por mes
    Contactar ahora
    Descripción detallada del producto
    Estándar de prueba: EN 702 e ISO 12127-1 Suministros de gas: Aire comprimido del propano y del aire
    Peso: 55 kg Garantía: 1 año
    Tamaño: 600 (D) X 250 (milímetro) X 650 (milímetro) Fuente de alimentación: 230 VCA 50 Hz, 10 A

    Contact Heat Transimmision Test Apparatus

    INTRODUCTION

    Contact Heat Transimmision Test Apparatus is applicable to protective clothing (including hand protectors) or its constituent materials intended to protect against high contact temperature. The application of the standard is restricted to contact temperatures from 100 °C to 500 °C.​

     

    FEATURE

    • The Contact Heat Transimmision Test Apparatus is designed and manufactured according to EN 702 and ISO 12127-1 standards.

    • ​The apparatus determines the threshold time of temperature rise of 10°C in the calorimeter.

    • ​In the test a heating cylinder is heated to a defined temperature and the specimen is put on the calorimeter.

    • During the measuring the calorimeter is moved towards the heating cylinder with a defined skipping speed of 5 mm/s and after contact a load of 49N is applied.

    • ​The temperature of the heating cylinder is adjustable from room temperature up to 500 °C.

    Installation requirements

    Electrical 230 volts Nominal 10 Amps
    Ambient Temperature Operating25±5℃
    Gas supplies Propane and air compressed air
    Dimensions

    600(D) X 250(mm) X 650(mm)

    Weight 55KG
    Applicable standards EN 702 and ISO 12127-1

     